Static Strainmeters
Measurement Box
This is a measurement box dedicated to T-ZACCS9 TS-960. The number of measuring point is 50, and various inputs such as strain gauges, strain gauge type transducers, thermocouples, Pt-RTDs and dc voltage can be measured. Owing to the introduction of our unique next-generation A/D conversion method that enables high-speed measurement with high accuracy and stability, and also of ultra high-speed field network that is based on Ethernet, highly accurate and stable measurement is enabled eliminating the influence of various thermoelectromotive forces, thermal zero shift of amplifier, and power line noise. Measurement is possible at intervals of 0.1 seconds in high-speed mode and 0.4 seconds in high-accuracy mode (in 50Hz area) regardless of the number of measuring point.


Features:
- Measures 1000 points in 0.1 seconds at the fastest by the adoption of ultra high-speed field network
- Highly accurate and stable measurement achieved by the adoption of our unique next-generation A/D conversion method that enables high-speed measurement with high accuracy and stability eliminating the influence of various thermoelectromotive forces, thermal zero shift of amplifier, and power line noise
- In high-accuracy mode, measures 1000 points in 0.4 seconds (in 50Hz area) even for thermocouple measurement and/or using high-resolution mode
- A temperature-integrated strain gauge can be measured using one channel
- Complete compensation method of strain (Comet) provided
- Various check functions (insulation check, sensitivity check, dispersion check, thermocouple burnout check)
Specifications
Type | EX-50H |
---|---|
Measurement object | Strain gauge, Strain gauge type transducer DC voltage, Thermocouple, Pt-RTD |
Number of measuring point | 50 points |
Measuring speed | High-speed mode 0.1 seconds High-accuracy mode 0.4 seconds(50Hz) / 0.34 seconds(60Hz) |
Number of connection | 20 boxes at maximum |
Extension distance | 100 m (between instruments) |
Connection cable | EX connection cable (CR-89**) |
External dimensions | 320 (W) × 130 (H) × 490 (D) mm |
Weight | Approx. 10 kg |
Power supply | AC 100 ~ 240 V 50/60 Hz 104 VA Max. |
This is a measurement box dedicated to T-ZACCS9 TS-963/-960. The number of measuring point is 10, and various inputs such as strain gauges, strain gauge type transducers, thermocouples, Pt-RTDs and dc voltage can be measured. Owing to the introduction of our unique next-generation A/D conversion method that enables high-speed measurement with high accuracy and stability, and also of ultra high-speed field network that is based on Ethernet, highly accurate and stable measurement is enabled eliminating the influence of various thermoelectromotive forces, thermal zero shift of amplifier, and power line noise. Measurement is possible at intervals of 0.1 seconds in high-speed mode and 0.4 seconds in high-accuracy mode (in 50Hz area) regardless of the number of measuring point.


Features:
- Measures 1000 points in 0.1 seconds at the fastest by the adoption of ultra high-speed field network
- Highly accurate and stable measurement achieved by the adoption of our unique next-generation A/D conversion method that enables high-speed measurement with high accuracy and stability eliminating the influence of various thermoelectromotive forces, thermal zero shift of amplifier, and power line noise
- In high-accuracy mode, measures 1000 points in 0.4 seconds (in 50Hz area) even for thermocouple measurement and/or using high-resolution mode
- A temperature-integrated strain gauge can be measured using one channel
- Complete compensation method of strain (Comet) provided
- Various check functions (insulation check, sensitivity check, dispersion check, thermocouple burnout check)
Specifications
Type | EU-10H |
---|---|
Measurement object | Strain gauge, Strain gauge type transducer DC voltage, Thermocouple, Pt-RTD |
Number of measuring point | 10 points |
Measuring speed | High-speed mode 0.1 seconds High-accuracy mode 0.4 seconds(50Hz) / 0.34 seconds(60Hz) |
Number of connection | 100 boxes at maximum (including the TS-960 built-in) |
Extension distance | 100 m (between instruments) |
Connection cable | EX connection cable (CR-89**) |
External dimensions | 320 (W) × 98(H) × 183 (D) mm |
Weight | Approx. 3 kg |
Power supply | AC 100 ~ 240 V 50/60 Hz 86 VA Max. |
This is a 10-channel measuring unit exclusively for TS-960/TS-963.
It can measure digital displacement sensors with 10 measurement points.Can be used with T-ZACCS BOX EX-10H, T-ZACCS UNIT EU-10H, and EU-10VO at the same time.
It can measure digital displacement sensors with 10 measurement points.Can be used with T-ZACCS BOX EX-10H, T-ZACCS UNIT EU-10H, and EU-10VO at the same time.

Features:
- Combined with T-ZACCS9 TS-963/-960, digital displacement sensor measurement is available
- Compatible with two types of digital displacement sensors
- No signal degradation because it is handled as a digital signal
- Can be used with T-ZACCS BOX EX-50H, T-ZACCS UNIT EU-10H, and EU-10VO at the same time
Switching box protocol converter for T-ZACCS9 TS-963/-960. The ISW-50G/IHW-50G switching boxes can be connected to the T-ZACCS9 TS-963/-960 for operation. One switching box can be operated with one unit of this converter.


Features:
- T-ZACCS9 TS-963/-960 enables measurement of switching box ISW-50G/IHW-50G
- Easy handling with no special settings required
- Corresponding to 1-gauge 4-wire measuring method
Specification
Type | EI-01P | |
---|---|---|
Function | Connection with switching box ISW-50G/IHW-50G *Measurement speed and sensor mode depend on switching box |
|
Connection with data logger | ||
Number of connectable units | Up to 20 units (in total including EX-50H) | |
Extension distance | 100m (between devices) | |
Connection cable | Connection cable for EX (CR-89**) | |
Connection with switching box | ||
Target model | IHW-50G, ISW-50G | |
ELECTRICAL (RS-422) | Number of connectable units | 1 unit, 50 points |
Extension distance | 160(W)×60(H)×171.5(D)mm | |
Connection cable | Extension cable for ISW/IHW(CR-832M) | |
Weight | Approx. 1 kg | |
Power supply | AC100 to 240V 50/60Hz 12VA MAX |
Repeaters for extending the communication distance between units, connecting between T-ZACCS 9 and T-ZACCS BOX / T-ZACCS UNIT or between T-ZACCS BOX / T-ZACCS UNIT and T-ZACCS BOX / T-ZACCS UNIT, to extend the 100 m distance between devices by a further The 100 m distance between devices can be extended by a further 100 m.


Features:
- This repeater can be used to extend the communication distance between devices by an additional 100 m
- Easy handling with no special configuration require
Specifications
Type | EE-00R |
---|---|
Function | Extended communication distance between units/td> |
Connection with data logger | |
Number of connectable units | Up to 99 connections |
Extension distance | 100m (between devices) |
Connection cable | Connection cable for EX (CR-89**) |
External dimensions | 160(W)×60(H)×171.5(D)mm |
Weight | Approx. 1 kg |
Power supply | AC100 to 240V 50/60Hz 12VA MAX |
Expandable by unit!
“T-ZACCS BOX AU-50”
The AU-50 consists of a master unit and a channel unit, which can be used with the TS-360 and TDS-540, and can be mixed with the conventional switchboxes ASW-50C/SSW-50D.
Multiple units can be connected to measure up to 1000 points.


Features:
- Combination of master and channel units
- Capable of measuring strain, DC voltage and thermocouples
- Up to 50 measurement points in one set
- The number of measuring points can be selected according to the number of channel units connected
- Built-in power booster for multipoint long-distance extension
- Supports the complete correction method for strain (Comet)
- T-ZACCS 3 Can be used with the TS-360 portable data logger and the TDS-540 data logger
Specifications
Type | T-ZACCS+ Master Unit AU-50M |
|
---|---|---|
Number of measurement points | Channel unit connection | Max 50 points (5 AU-10 or AU-10-05 units in total) |
Strain measurement | Depends on the data logger being combined | |
DC voltage measurement | Depends on the data logger being combined | |
Thermocouple temperature measurement | Depends on the data logger being combined | |
Sensor mode | Set for each point from the data logger | |
Channel unit connection | Applicable model | AU-10, AU-10-05 |
Number of connected units | Up to 5 | |
Data logger connection | Applicable model | TDS-540, TS-360(AU-50MA) |
Extension distance | Depends on the data logger being combined | |
connecting cable | Switching box connection cable(CR-65) | |
Dimensions | AU-50M:280(W)×45(H)×60(D)mm AU-10:280(W)×45(H)×60(D)mm →Total size:280(W)×270(H)×50(D)mm *AU-10 (when 5 units are connected) *Excluding rubber protector and protruding parts |
|
Weight | Approx. 800 g | |
Power supply | Usually supplied by data loggers |
To add measuring channels to the TS-360 portable data logger, connect the AU-10/AU-10-05 channel unit!
Unit to add 10 measuring points. Set the unit number using the digital switch and assign a channel number to each measuring point of the unit. The channel unit is connected to the driver unit AU-50MA or the master unit AU-50M.
During measurement, the LED corresponding to the measurement channel lights up and the LED emission colour varies depending on the sensor mode type (LED emission colour Strain measurement: red, DC voltage measurement: blue, thermocouple temperature measurement: green).


Features:
- Up to 5 additional units can be added against the T-ZACCS+ master unit
- When used as a switching box, it can be used with conventional data loggers such as TDS-540 and can be mixed with conventional switch boxes ASW-50C/SSW-50D
- Up to 5 additional units for T-ZACCS+ driver units or master units
Specifications
Type | T-ZACCS UNIT Channel Unit AU-10/AU-10-05 |
---|---|
Number of measurement points | 10 points |
Input terminal | Dual-use screw-mounted and soldered type |
One-touch connector | NDIS One-touch connector (AU-10-05 only) |
Power supply | Supplied by AU-50MA/AU-50M |
Dimensions | AU-10:280(W)×45(H)×60(D)mm AU-10-05:280(W)×45(H)×80(D)mm *Excluding rubber protector and protruding parts |
Weight | AU-10: approx. 900 g AU-10-05: approx. 1.2 kg |