Other Instruments
Dynamic Strainmeters Optional Accessory
The bridge boxes are used for connecting strain gauges in several bridge methods including quarter bridge and half bridge. Fixed resistors for configuring a Wheat stone bridge circuit are inside of the bridge box. For strain gauge based transducers of full bridge configuration, if the transducer is without connector plug on its cable end, it is connected to a dynamic strainmeter using a bridge box by connecting cable wires to the bridge box terminals. The bridge method is determined by the way of connection to the terminals or by the setting of switches depending on the type of bridge box.

Type | SB-122A-2/4/6/8/10 |
---|---|
Number of Channels | SB-122A-2: 2 channel SB-122A-4: 4 channel SB-122A-6: 6 channel SB-122A-8: 8 channel SB-122A-10: 10 channel |
Bridge Method | Quarter Bridge 2-wire, Quarter Bridge 3-wire 120Ω, Half Bridge, Full Bridge 60 to 1000Ω |
Connection | Screwing or soldering |
Dimensions | SB-122A-2: 55(W)×35(H)×100(D)mm SB-122A-4: 105(W)×35(H)×100(D)mm SB-122A-6: 155(W)×35(H)×100(D)mm SB-122A-8: 205(W)×35(H)×100(D)mm SB-122A-10: 255(W)×35(H)×100(D)mm |
Weight | SB-122A-2: Approx. 0.4kg SB-122A-4: Approx. 0.6kg SB-122A-6: Approx. 0.8kg SB-122A-8: Approx. 1.0kg SB-122A-10: Approx. 1.2kg |
Option | CR-612 attached (the same quantity as the number of channels) |
Type | SB-123A/SB-353A |
---|---|
Number of channels | 1 channel |
Bridge method | Quarter Bridge, Quarter Bridge 3-wire, Opposite Half Bridge, Opposite Half Bridge 3-wire SB-123A: 120 Ω SB-353A: 350 Ω Half Bridge, Full Bridge: 60 to 1000 Ω |
Connecting terminal | Clamp type quick connecting terminal |
Dimensions | 30(W) x 30(H) x 90(D) mm (except projecting parts) |
Weight | Approx. 100 g |
Option | CR-612 attached |
Type | SB-120SB-8/SB-120SB-10 |
---|---|
Number of channels | 2 channels: SB-120SB-2 4 channels: SB-120SB-4 6 channels: SB-120SB-6 8 channels: SB-120SB-8 10 channels: SB-120SB-10 |
Input Connector | Terminal: M3 x 5P terminal Connectors: NDIS 7P connector receptacle |
Bridge method | Quarter Bridge 3-wire (Quarter Bridge with short-circuit bar) 120 Ω Half Bridge, Full Bridge 60 to 1000 Ω |
Connection | Screwing, soldering or plugging |
Dimensions | SB-120SB-8: 205(W) × 35(H) × 100(D)mm SB-120SB-10: 255(W) × 35(H) × 100(D)mm |
Weight | SB-120SB-8: Approx. 1.2kg SB-120SB-10: Approx. 1.4kg |
Option | CR-612 attached (8pcs. for SB-120SB-8, 10pcs. for SB-120SB-10) |
The carrying case/mounting rack is used for housing DA/DC series dynamic strainmeters to configure a multi-channel measurement system. The case/rack has a power switch, calibration switch and balancing button for operating all channels at the same time.
This case is used to configure DA series or DC series units in multi-channel. A power switch, calibration switch, and balancing button are provided that can be used with all channels at the same time.
This case is used to configure DA series or DC series units in multi-channel. A power switch, calibration switch, and balancing button are provided that can be used with all channels at the same time.

Type | SB-122A-2/4/6/8/10 |
---|---|
Number of Channels | SB-122A-2: 2 channel SB-122A-4: 4 channel SB-122A-6: 6 channel SB-122A-8: 8 channel SB-122A-10: 10 channel |
Bridge Method | Quarter Bridge 2-wire, Quarter Bridge 3-wire 120Ω, Half Bridge, Full Bridge 60 to 1000Ω |
Connection | Screwing or soldering |
Dimensions | SB-122A-2: 55(W)×35(H)×100(D)mm SB-122A-4: 105(W)×35(H)×100(D)mm SB-122A-6: 155(W)×35(H)×100(D)mm SB-122A-8: 205(W)×35(H)×100(D)mm SB-122A-10: 255(W)×35(H)×100(D)mm |
Weight | SB-122A-2: Approx. 0.4kg SB-122A-4: Approx. 0.6kg SB-122A-6: Approx. 0.8kg SB-122A-8: Approx. 1.0kg SB-122A-10: Approx. 1.2kg |
Option | CR-612 attached (the same quantity as the number of channels) |
Type | SB-123A/SB-353A |
---|---|
Number of channels | 1 channel |
Bridge method | Quarter Bridge, Quarter Bridge 3-wire, Opposite Half Bridge, Opposite Half Bridge 3-wire SB-123A: 120 Ω SB-353A: 350 Ω Half Bridge, Full Bridge: 60 to 1000 Ω |
Connecting terminal | Clamp type quick connecting terminal |
Dimensions | 30(W) x 30(H) x 90(D) mm (except projecting parts) |
Weight | Approx. 100 g |
Option | CR-612 attached |
Type | SB-120SB-8/SB-120SB-10 |
---|---|
Number of channels | 2 channels: SB-120SB-2 4 channels: SB-120SB-4 6 channels: SB-120SB-6 8 channels: SB-120SB-8 10 channels: SB-120SB-10 |
Input Connector | Terminal: M3 x 5P terminal Connectors: NDIS 7P connector receptacle |
Bridge method | Quarter Bridge 3-wire (Quarter Bridge with short-circuit bar) 120 Ω Half Bridge, Full Bridge 60 to 1000 Ω |
Connection | Screwing, soldering or plugging |
Dimensions | SB-120SB-8: 205(W) × 35(H) × 100(D)mm SB-120SB-10: 255(W) × 35(H) × 100(D)mm |
Weight | SB-120SB-8: Approx. 1.2kg SB-120SB-10: Approx. 1.4kg |
Option | CR-612 attached (8pcs. for SB-120SB-8, 10pcs. for SB-120SB-10) |
This adaptor is intended for temperature measurement by T or K type thermocouple using a DC exciting strainmeter. No external power source is required because the adaptor uses bridge excitation supplied from the strainmeter. It is small-sized and can be directly connected to the connector of a strainmeter, thus saving space for installation.

The bridge boxes are used for connecting strain gauges in several bridge methods including quarter bridge and half bridge. Fixed resistors for configuring a Wheat stone bridge circuit are inside of the bridge box. For strain gauge based transducers of full bridge configuration, if the transducer is without connector plug on its cable end, it is connected to a dynamic strainmeter using a bridge box by connecting cable wires to the bridge box terminals. The bridge method is determined by the way of connection to the terminals or by the setting of switches depending on the type of bridge box.