The CLA-NA Load Cell has a diaphragm type strain sensing element. It is compact, easy to operate and can be used to take consistent measurement.

Protection ratings : IP 67 equivalent

Features

  • Splash-proof structure, Stable measurement
  • Small, Easy handling

📄 Data Sheet >


Specifications

TYPECLA-500NACLA-1KNACLA-2KNACLA-5KNACLA-10KNACLA-20KNA
Capacity500N1kN2kN5kN10kN20kN
Rated Output1.5mV/V (3000×10⁻⁶ strain) ±0.5%
Non-linearity0.2%RO
Hysteresis0.1%RO
Natural frequency6.1kHz8.9kHz13kHz19kHz24kHz28kHz
Temperature effect on zero0.01%RO/°C
Temperature effect on span0.01%/°C
Compensated temperature range-10 ~ +60°C
Allowable temperature range-20 ~ +70°C
Over load150%
Input/Output resistance350Ω ±2%
Recommended exciting voltage6V or less
Allowable exciting voltage15V
Zero balance5%RO
Weight0.36kg0.38kg
Input/Output cable: φ6mm 0.35mm² 4-core shielded chloroprene cable 5m

CLP-NB The CLP-NB is a general purpose compression load cell having a column shape strain sensing element. A variety of capacities ranging from 10 kN to 10 MN is available. Dual output type having two independent inputs and outputs is also available on request.

Protection ratings : IP 65 equivalent

Features

  • Load cell having appropriate capacity can be chosen among various types
  • Easy to handle
  • CE marking compliant

📄 Data Sheet >


Specifications

TypeCLP-
10KNB
CLP-
20KNB
CLP-
30KNB
CLP-
50KNB
CLP-
100KNB
CLP-
200KNB
CLP-
300KNB
CLP-
500KNB
CLP-
1MNB
CLP-
2MNB
CLP-
3MNB
CLP-
5MNB*
CLP-
10MNB*
Capacity10kN20kN30kN50kN100kN200kN300kN500kN1MN2MN3MN5MN10MN
Rated Output1.5mV/V (3000×10⁻⁶ strain) ±0.2%
Non-linearity0.1%RO0.2%RO
Hysteresis0.1%RO
Natural frequency7.5kHz9.2kHz11kHz14kHz19kHz16kHz11kHz13kHz13kHz7.0kHz5.8kHz4.5kHz2.7kHz
Temperature effect on zero0.01%RO/°C
Temperature effect on span0.005%/°C
Compensated temperature range-10 ~ +60°C
Allowable temperature range-20 ~ +70°C
Overload150%
Input/Output resistance350Ω ±1%
Recommended exciting voltage10V or less
Allowable exciting voltage20V
Zero balance5%RO
Weight1.1kg1.1kg1.1kg1.1kg1.2kg2.0kg4.2kg4.6kg10kg24kg33kg70kg190kg
Input/Output cable : CT9-4N10/WP-STB (φ9mm 0.5mm2 4-core shielded chloroprene cable 10m) * Made-to-order

The CLU-NA Load Cell is an inert-gas encased load cell in a hermetically sealed package. The strain sensing element has a simple structure that enables highly precise and consistent measurements over long periods of time.
Two independent output type is also available on request.

Protection ratings : IP 65 equivalent

Features

  • Long-term stable measurement
  • Easy handling

Data Sheet >


Specifications

TYPECLU-10KNACLU-20KNACLU-50KNACLU-100KNACLU-200KNACLU-500KNACLU-1MNA
Capacity10kN20kN50kN100kN200kN500kN1MN
Rated Output2mV/V (4000×10⁻⁶ strain) ±0.2%
Non-linearity0.15%RO
Hysteresis0.05%RO
Natural frequency5.2kHz9.5kHz12kHz13kHz11kHz9kHz7kHz
Temperature effect on zero0.005%RO/°C
Temperature effect on span0.005%/°C
Compensated temperature range-10 ~ +60°C
Allowable temperature range-30 ~ +80°C
Over load150%
Input/Output resistance350Ω±1%
Recommended exciting voltage10V or less
Allowable exciting voltage20V
Zero balance5%RO
Weight2.2kg2.2kg2.2kg3.2kg4.3kg11kg15kg
Input/Output cable : φ9mm 0.5mm2 4-core shielded chloroprene cable 5m

The CLG-NB Load Cell is a high precision load cell in a thin, hermetically sealed package. It is widely used in tight spaces and as a system sensor for industrial machinery.

Two independent output type is also available on request.

Protection ratings : IP 67 equivalent

Features

  • Hermetically sealed, High precision, High stability
  • Low profile, Easy to install
  • Most applicable as system sensor for industrial machines

Data Sheet >


Specifications

TYPECLG-10KNBCLG-20KNBCLG-50KNBCLG-100KNBCLG-200KNB
Capacity10kN20kN50kN100kN200kN
Rated Output2mV/V (4000×10⁻⁶ strain) ±0.5%
Non-linearity0.2%RO
Hysteresis0.2%RO
Natural frequency10kHz13kHz13kHz13kHz13kHz
Temperature effect on zero0.01%RO/°C
Temperature effect on span0.005%RO/°C
Compensated temperature range-10 ~ +60°C
Allowable temperature range-20 ~ +70°C
Over load150%
Input/Output resistance350Ω ±1%
Recommended exciting voltage6V or less
Allowable exciting voltage15V
Zero balance5%RO
Weight0.9kg0.9kg1.8kg2.6kg3.8kg
Input/Output cable: CLG-10KNB, 20KNB : φ6mm 0.35mm² 4-core shielded chloroprene cable 5m
CLG-50KNB~200KNB : φ9mm 0.5mm² 4-core shielded chloroprene cable 5m