Load Cells
Flat Compression Load Cell
CLL-NA The CLL-NA load cells with a flat loading platform are used to conduct loading tests on cylindrical concrete specimens. A cylindrical concrete specimen can be directly set on the surface of the loading platform. By using this load cell together with the compressometer, it is possible to measure load and strain simultaneously.
Protection ratings : IP 65 equivalent
Features
- Guide marking for right placement of specimens with different sizes
- Easy handling
Specifications
TYPE | CLL-500KNA | CLL-1MNA |
---|---|---|
Applicable specimen | φ10х20cm | φ15х30cm |
Capacity | 500kN | 1MN |
Rated Output | 1.5mV/V (3000×10-6 strain) ±0.5% | |
Non-linearity | 0.2%RO | |
Hysteresis | 0.2%RO | |
Temperature effect on zero | 0.01%RO/°C | |
Temperature effect on span | 0.01%/°C | |
Compensated temperature range | -10 ~ +60°C | |
Allowable temperature range | -20 ~ +70°C | |
Overload | 150% | |
Input/Output resistance | 350Ω±2% | |
Recommended exciting voltage | 10V or less | |
Allowable exciting voltage | 20V | |
Zero balance | 5%RO | |
Weight | 9kg | 22kg |
Supplied cable : CT9-4N10/WP-STB (φ9mm 0.5mm2 4-core shielded chloroprene cable 10m)
The CLH-NA is designed mainly to test a cylindrical test specimen made of high-strength concrete. The cylindrical specimen can be directly set on the top of load cell. Also, by using the load cell together with a compressometer, it is possible to measure load and strain simultaneously.
Protection ratings : IP 65 equivalent
Features
- Guide marking for right placement of specimens with different sizes.
- Easy handling
Specifications
TYPE | CLH-1MNA | CLH-1.5MNA | CLH-2MNA |
---|---|---|---|
Applicable specimen | φ10х20cm | φ12.5х25cm | φ15х30cm |
Capacity | 1MN | 1.5MN | 2MN |
Rated Output | 1.5mV/V (3000×10-6 strain) ±0.5% | ||
Non-linearity | 0.2%RO | ||
Hysteresis | 0.2%RO | ||
Temperature effect on zero | 0.01%RO/°C | ||
Temperature effect on span | 0.01%/°C | ||
Compensated temperature range | -10 ~ +60°C | ||
Allowable temperature range | -20 ~ +70°C | ||
Overload | 150% | ||
Input/Output resistance | 350Ω±2% | ||
Recommended exciting voltage | 10V or less | ||
Allowable exciting voltage | 20V | ||
Zero balance | 5%RO | ||
Weight | 10kg | 14kg | 26kg |
Supplied cable : CT9-4N10/WP-STB (φ9mm 0.5mm2 4-core shielded chloroprene cable 10m)
The CLF-NA Load Cell is a thin load cell with a flat load bearing surface. It is widely used as a load sensor for industrial machinery, especially when measuring loads on rolling machines or measuring compression force on presses.
Protection ratings : IP 65 equivalent
Features
- Can be used in tight spaces in thin
- Excellent stability
- Optimum for rolling machine and press machine
Specifications
TYPE | CLF-500KNA | CLF-1MNA | CLF-1.5MNA | CLF-2MNA |
---|---|---|---|---|
Capacity | 500kN | 1MN | 1.5MN | 2MN |
Rated Output | 2mV/V (4000×10-6 strain) ±0.5% | |||
Non-linearity | 0.3%RO | |||
Hysteresis | 0.2%RO | |||
Temperature effect on zero | 0.01%RO/°C | |||
Temperature effect on span | 0.005%/°C | |||
Compensated temperature range | -10 ~ +60°C | |||
Allowable temperature range | -20 ~ +70°C | |||
Overload | 150% | |||
Input/Output resistance | 350Ω±2% | |||
Recommended exciting voltage | 10V or less | |||
Allowable exciting voltage | 20V | |||
Zero balance | 5%RO | |||
Weight | 6kg | 8kg | 10kg | 13kg |
Supplied cable : CT9-4N10/WP-STB (φ9mm 0.5mm2 4-core shielded chloroprene cable 10m)
The CLF-NA Load Cell is a thin load cell with a flat load bearing surface. It is widely used as a load sensor for industrial machinery, especially when measuring loads on rolling machines or measuring compression force on presses.
Protection ratings : IP 65 equivalent
Features
- Can be used in tight spaces in thin
- Excellent stability
- Rolling machine, press machine suitable
Specifications
TYPE | CLF-3MNA | CLF-5MNA | CLF-10MNA |
---|---|---|---|
Capacity | 3MN | 5MN | 10MN |
Rated Output | 1.5mV/V (3000×10-6 strain) ±0.5% | ||
Non-linearity | 0.3%RO | ||
Hysteresis | 0.2%RO | ||
Temperature effect on zero | 0.01%RO/°C | ||
Temperature effect on span | 0.005%/°C | ||
Compensated temperature range | -10 ~ +60°C | ||
Allowable temperature range | -20 ~ +70°C | ||
Overload | 150% | ||
Input/Output resistance | 350Ω±2% | ||
Recommended exciting voltage | 10V or less | ||
Allowable exciting voltage | 20V | ||
Zero balance | 5%RO | ||
Weight | 40kg | 66kg | 150kg |