Roorkee, Uttarakhand India +91-8979900000 sales@recordtek.com Serving your measurement needs for decades

Solution Integrator

Leading Strain Gauge

Certified


Load Cells

Tension / Compression Load Cell

The TCLB-NA Tension/Compression Universal Load Cell is a low capacity load cell. It can be used for high precision measurement because the internal structure uses both ends fixation beam for the strain sensing element.

Protection ratings :
TCLB-50NA IP 40 equivalent
TCLB-100NA/-200NA IP 42 equivalent

Features

  • Low-capacity, High precision
  • Small, Light weight

📄 Data Sheet >


Specifications

TYPETCLB-50NATCLB-100NATCLB-200NA
Capacity50N100N200N
Rated Output1.5mV/V (3000×10-6 strain) ±0.5%
Non-linearity0.1%RO
Hysteresis0.1%RO
Natural Frequency0.9kHz1.4kHz2kHz
Temperature effect on zero0.01%RO/°C
Temperature effect on span0.01%/°C
Compensated temperature range-10 ~ +60°C
Allowable temperature range-20 ~ +70°C
Overload150%
Input/Output resistance350Ω±2%
Recommended exciting voltage6V or less
Allowable exciting voltage15V
Zero balance5%RO
Weight0.45kg0.9kg
Input/Output cable :
φ9mm 0.5mm2 4-core shielded chloroprene cable 5m

The TCLA-NB Tension/Compression Universal Load Cell comes to much smaller and lightweight than conventional TCLA-NA. High capacity ranges of 10kN and 20kN are added on the line. It is hermetically sealed, enabling highly precise and consistent measurement.

Protection ratings : IP 67 equivalent

Features

  • Small, Lightweight
  • Tension and compression
  • Hermetically sealed structure
  • Stable measurement
  • Easy handling

📄 Data Sheet >


Specifications

TYPETCLA-500NBTCLA-1KNBTCLA-2KNBTCLA-5KNBTCLA-10KNBTCLA-20KNB
Capacity500N1kN2kN5kN10kN20kN
Rated Output1.5mV/V (3000×10-6 strain) ±2%1.5mV/V (3000×10-6 strain) ±1%2.0mV/V (4000×10-6 strain) ±1%
Non-linearity0.3%RO0.2%RO
Hysteresis0.1%RO
Natural Frequency4.5kHz6.7kHz8.5kHz13kHz17kHz16kHz
Temperature effect on zero0.01%RO/°C
Temperature effect on span0.01%/°C
Compensated temperature range-10 ~ +60°C
Allowable temperature range-20 ~ +70°C
Overload150%120%
Input/Output resistance350Ω±2%
Recommended exciting voltage6V or less
Allowable exciting voltage15V
Zero balance5%RO
Weight0.6kg0.7kg
Input/Output cable :
φ6mm 0.35mm2 4-core shielded chloroprene
cable 5m

The TCLK-NA Tension/Compression Universal Load Cell has a low profile construction that serves to save installation space.

Protection ratings : IP 67 equivalent

Features

  • Hermetically sealed structure
  • Stable measurement
  • Small, Lightweight, Low height
  • Small deflection
  • Suitable for testing machines

Data Sheet >


Specifications

TYPETCLK-5KNATCLK-10KNATCLK-20KNATCLK-50KNA
Capacity5kN10kN20kN50kN
Rated Output2mV/V (4000×10-6 strain) ±1%
Non-linearity0.1%RO
Hysteresis0.1%RO
Natural Frequency18kHz17kHz17kHz14kHz
Temperature effect on zero0.01%RO/°C
Temperature effect on span0.01%/°C
Compensated temperature range-10 ~ +60°C
Allowable temperature range-20 ~ +70°C
Overload150%
Input/Output resistance350Ω±2%
Recommended exciting voltage6V or less
Allowable exciting voltage15V
Zero balance5%RO
Weight0.45kg0.8kg1.3kg2.6kg
Input/Output cable :
TCLK-5KNA  &nbsp φ3mm 0.05mm2 4-core shielded chloroprene cable 5m
TCLK-10KNA~-50KNA     φ6mm 0.35mm2 4-core shielded
chloroprene cable 5m

The TCLP-NB Tension/Compression Universal Load Cell is a load cell widely used in applications such as measuirng crane and jack loads because it offers excellent consistency.
This load cell is available with built-in two isolated input / output on request.

Protection ratings : IP 65 equivalent

Features

  • Easy handling
  • Excellent stability
  • Many load ranges for selection according to purposes

Data Sheet >


Specifications

TYPETCLP-
10KNB
TCLP-
20KNB
TCLP-
30KNB
TCLP-
50KNB
TCLP-
100KNB
TCLP-
200KNB
TCLP-
300KNB
TCLP-
500KNB
TCLP-
1MNB
TCLP-
1.5MNB*
TCLP-
2MNB
Capacity10kN20kN30kN50kN100kN200kN300kN500kN1MN1.5MN2MN
Rated Output1mV/V (2000×10-6 strain) ±0.5%
Non-linearity0.1%RO0.3%RO
Hysteresis0.1%RO0.3%RO
Natural Frequency6.8kHz7.9kHz8.3kHz10kHz10kHz7.7kHz6.7kHz5.3kHz4kHz3.1kHz2.6kHz
Temperature effect on zero0.01%RO/°C
Temperature effect on span0.005%/°C
Compensated temperature range-10 ~ +60°C
Allowable temperature range-20 ~ +70°C
Overload200%
Input/Output resistance350Ω±1%
Recommended exciting voltage10V or less
Allowable exciting voltage20V
Zero balance5%RO
Weight1.5kg1.5kg2kg2kg2.5kg5kg8kg15kg50kg85kg110kg
Supplied cable : CT9-4N10/WP-STB (φ9mm 0.5mm2 4-core shielded chloroprene cable 10m)   *Made-to-order

The TCLU-NA Tension/Compression Universal Load Cell is an inert-gas encased load cell in a hermetically sealed package. It can take highly precise and consistent measurements over long periods of time, and is used primarily in applications such as measuring crane and jack loads.
This load cell is available with built-in two isolated input / output on request .

Protection ratings : IP 65 equivalent

Features

  • High precision, High output
  • Excellent stability
  • Easy handling

Data Sheet >


Specifications

TYPETCLU-
10KNA
TCLU-
20KNA
TCLU-
50KNA
TCLU-
100KNA
TCLU-
200KNA
Capacity10kN20kN50kN100kN200kN
Rated Output2mV/V (4000×10-6 strain) ±0.5%
Non-linearity0.15%RO
Hysteresis0.05%RO
Natural Frequency4.8kHz5.3kHz6.0kHz4.8kHz2.4kHz
Temperature effect on zero0.005%RO/°C
Temperature effect on span0.005%/°C
Compensated temperature range-10 ~ +60°C
Allowable temperature range-30 ~ +80°C
Overload150%
Input/Output resistance350Ω±1%
Recommended exciting voltage10V or less
Allowable exciting voltage20V
Zero balance5%RO
Weight4kg4kg4kg11kg18kg
Input/Output cable : φ9mm 0.5mm2 4-core shielded chloroprene cable 5m

Accordion Content

Compared with TML ordinary Tension/Compression Universal Load Cells, the TCLN-NA is very small and light model. The Input/Output cable is as thin as 3mm in diameter for easiness to handle.

Protection ratings : IP 67 equivalent

Features

  • Airtight structure enabling stable measurement
  • Compact and lightweight, easy handling

Data Sheet >


Specifications

TYPETCLN-500NATCLN-1KNATCLN-2KNATCLN-5KNA
Capacity500N1kN2kN5kN
Rated Output1mV/V (2000×10-6 strain) ±20%
Non-linearity0.5%RO
Hysteresis0.1%RO
Natural Frequency10kHz12kHz14kHz14kHz
Temperature effect on zero0.05%RO/°C
Temperature effect on span0.05%/°C
Compensated temperature range-10 ~ +60°C
Allowable temperature range-20 ~ +70°C
Overload150%
Ultimate overload rating200%
Input/Output resistance350Ω±1%
Recommended exciting voltage6V or less
Allowable exciting voltage15V
Zero balance10%RO
Weight80g80g80g140g
Input/Output cable : φ3mm 0.05mm2 4-core shielded
chloroprene cable 5m